“How to fix an Aisan fuel regulator” is a common question for equipment owners, so we, at Intella, decided to create an outline on how to fix one. Given how important the fuel regulator is to your equipment, it’s important to keep them well intact. This blog will give step by step directions on how to fix your regulator.
Brief Aisan Fuel Regulator Introduction
Aisan fuel systems are used in a variety of different forklifts including Toyota, Hyster, and Yale. Aisan is partly owned by Toyota so you see mainly see these regulators in Toyota forklifts.
Rebuild or Replace the Entire Unit
Rebuilding an Aisan regulator is a bit more difficult than the traditional and popular Impco model J. Depending on your skill level, you might want to simply replace the entire unit.
How to Rebuild the Aisan Regulator
Remove solenoid from unit
Remove back studs with socket
Remove seals and pad
Remove screws
Remove parts from new Aisan repair kit
Re-install valve parts
Re-install back cover
Install diaphragm
Install o-ring and spring
Re-install pad and oring
Re-install sintered metal filter
Re-install solenoid
For full length YouTube video: Click Here
Buying an Aisan Fuel Regulator
Looking to purchase an Aisan fuel regulator? Buy one here! If you have any other questions, please call us at 616-796-6638 and speak to one of our industry renowned customer support specialists.